KCN-□WT-□ replace the two-stage setting

Question

Question

I would like to replace the KCN- □ WT- □ used in the Double setting.
Please tell me the successor model and update procedure when updating to the current product.

Answer

Answer

The successor model will be the KCV series.
However, some operation modes cannot be partially replaced.
Since there are differences in specifications, please check the following notes when replacing.

Replace

Model number comparison table

KCN-W series KCV series remarks
KCN-4WT KCV-4S 4-digit AC power supply transistor output
KCN-6WT KCV-6S 6-digit AC power supply transistor output
KCN-4WT-C KCV-4S-C 4-digit DC power supply transistor output
KCN-6WT-C KCV-6S-C 6-digit DC power supply transistor output

Notes


1.The maximum counting speed is different.(KCN-W:5kHz→KCV:10kHz)

2.KCN-The terminal block arrangement and setup menu items / display order are different between W and KCV.

3.The key protection method is different.

4.KCV does not output when the set value is 0.

5.The depth dimension of the product is different. (AC power supply: + 10mm, DC power supply: + 5mm)

6.Set the KCV with prediction output setting to the KCN Preset value “SET2-SET1 value”.

7.The output of KCV (OUT2) is the contact output.

About operation

mode OUT1 OUT2 Replaceability
Hold output / continue counting Hold output / continue counting
Hold output / continue counting One-shot output / counting reset ×
Hold output / continue counting One-shot output / counting continuation ×
Hold output / continue counting Hold output / count hold ×
One-shot output / counting continuation Hold output / continue counting ×
One-shot output / counting continuation One-shot output / counting reset ×
Count value ≥ 1st set value Count value ≤ 2nd set value ×
Count value ≥ 1st set value Count value ≥ 2nd set value ×
Count value < first set value 1st set value ≤ count value ≤ 2nd set value ×

Input connection method

KCV_input

Output connection method

KCV_output

Preset value

Both KCN-W / KT-V are set with each digit key.

Settings in setup mode

The setting order of the setup mode menu is different between KCN-W and KT-V.
In addition, some functions have changed to DIP SW settings.
Please set up referring to the figure below.