How Can We Help?
< All Topics
Print

KCV-□T replace

Question

Question

The total counter KCV- □ T is continuously used.
I heard that it will be abolished due to model number integration, but which is the alternative model?

Answer

Answer

The alternative model is the KCV- □ S series.
Please check the following notes when replacing.

Replacement

Model number comparison table

KCV- □ T series KCV- □ S series remarks
KCV-4T KCV-4S 4-digit AC power supply
KCV-6T KCV-6S 6-digit AC power supply
KCV-4T-C KCV-4S-C 4-digit DC power supply
KCV-6T-C KCV-6S-C 6-digit DC power supply

Notes


1. Turn off the dip SW3 and set the addition mode.

2. Turn on the dip SW5 and set the output mode to the retention mode.

3. It is recommended to turn on the dip SW6 and protect the digit key in the setup mode.

4. You can set any number of Preset values ​​and prediction values, but it is recommended to set them to zero.

Product

Related manual

Related keywords

Inquiry

Previous KCV Forecast settings