How Can We Help?
SJ Series Replacement

Question
I heard that the SJ series has been abolished.
Which successor should I choose?

Answer
The successor will be the SJ-ETHER series.
Please read the following notes before replacing.
SJ series | SJ-ETHER series |
SJ-00DD1-D | SJ-11DD1E-D or SJ-11DD1EP-D |
SJ-00DD2-D | SJ-11DD2E-D or SJ-11DD2EP-D |
SJ-00DR-D | SJ-11DRE-D or SJ-11DREP-D |
SJ-00AR-D | SJ-11DRE-D or SJ-11DREP-D +J-08NA added |
SJ-02DD1-D | SJ-12DD1E-D or SJ-12DD1EP-D |
SJ-02DD2-D | SJ-12DD2E-D or SJ-12DD2EP-D |
SJ-02DR-D | SJ-12DRE-D or SJ-12DREP-D |
SJ-30DD1-D | No successor model |
Overview
The SJ-ETHER series has significantly improved performance and functions over the old SJ series.
Along with this, some of the specifications have also changed, and there are some precautions when replacing it.
Along with this, some of the specifications have also changed, and there are some precautions when replacing it.
Difference in extended I / O number
SJ series
4 points / 8 points I / O are automatically assigned to 8 points, and 16 points I / O are automatically assigned to 16 points in ascending numerical order.

SJ-ETHER series
The first numbers 100 to 1000 of each expansion slot 1 to 8 are fixedly assigned.

Ladder programming tools available
SJ series
DirectSOFT5.1 Build34
KPP(Koyo PLC Programming Software)
KPP(Koyo PLC Programming Software)
SJ-ETHER series
KPP(Koyo PLC Programming Software)
Programmer: S-20P (* Some functions are limited)
Programmer: S-20P (* Some functions are limited)
High-speed input / output function
The high-speed input / output function of the SJ series has been greatly enhanced.
Dedicated instructions are provided for the high-speed counter function and motion control function, making it extremely easy to use.
Input / output function settings can also be easily set from KPP.
If the high-speed counter function is used in the SJ series, the program in this part cannot be diverted, so it is necessary to change the program by referring to the following manual.
CPU built-in analog input / output setting method
Special register for setting the function of analog input / output with built-in CPU: The specification method of R7600 is different.
In addition, SJ-ETHER can be set not only from R7600 but also from KPP’s I / O configuration function.
For details, see “Built-in analog data input / output function” in Chapter 3 of the User’s Manual.
Product

SJ-Click here for details on the Ether series

PLC Click here for details on the programming software KPP
Related manual
SJ-ETHER User’s Manual
SJ-ETHER User’s Manual High Speed Counter Edition
SJ-ETHER User’s Manual Motion Edition
SJ Series User’s Manual
Related keywords
Inquiry
technical support
Click here for inquiries by email
Click here for inquiries by email